Detergents, rinses, and enemas screening tests

Summary

Lotion (Chinese Pharmacopoeia, 2010 Edition, Part II, Appendix I S) means a solution, emulsion, or suspension containing a drug for cleansing or applying to unbroken skin. Flushing agent (Chinese Pharmacopoeia, 2010 Edition, Part II, Appendix 1 S) means a sterile solution for flushing open wounds or cavities. Enema (Chinese Pharmacopoeia, 2010 Edition, Part II, Appendix I S) means a liquid preparation of a watery or oily solution or suspension that is instilled into the rectum for therapeutic, diagnostic or nutritional purposes.

Operation method

"Volume" checking method

Principle

Lotion (Chinese Pharmacopoeia, 2010 Edition, Part II, Appendix I S) means a solution, emulsion, or suspension containing a drug for cleansing or applying to unbroken skin. Flushing agent (Chinese Pharmacopoeia, 2010 Edition, Part II, Appendix 1 S) means a sterile solution for flushing open wounds or cavities. Enema (Chinese Pharmacopoeia, 2010 Edition, Part II, Appendix I S) means a watery, oily solution or suspension that is instilled into the rectum as a liquid preparation for therapeutic, diagnostic or nutritional purposes. The quality requirements for lotions, rinses and enemas, in addition to non-toxicity, non-local irritation, as well as the Pharmacopoeia species of the items specified under the check, should check the "volume". Wash, enema should also check the "microbial limit"; rinse agent in addition to checking the "sterility", should also check the "bacterial endotoxin" or "pyrogen". ". Flushing agents should be clarified by visual inspection under appropriate conditions.

Materials and Instruments

Detergents Flushing agents Enemas
Water
Analytical balances

Move

I. Brief description
Unless otherwise specified, this method is applicable to the loading check of detergents, rinsing agents and enemas. It shall be checked according to the "minimum loading check method" and shall comply with the regulations.
II. Methods of transportation
Unless otherwise specified, inspection in accordance with the Standard Practice for Minimum Load Inspection Method shall be in accordance with the provisions.

Caveat

1. When opening the container, care should be taken to avoid loss; care should be taken to keep the mouth of the container clean so that no foreign matter can be brought into the test material.

2. The suspension should be shaken well before doing the loading check.


For more product details, please visit Aladdin Scientific website.

https://www.aladdinsci.com/

Categories: Protocols